Self-monitoring of glucose: doctor's and patient's view

https://doi.org/10.21518/2079-701X-2014-17-104-107

Abstract

Self-monitoring of blood glucose is the main tool in the management of diabetes mellitus (DM) utilized by both doctor and patient. On the one hand, self-monitoring of blood glucose is necessary to achieve and maintain adequate glycemic control; on the other hand, it is an invasive and stressful procedure. In order to make self-monitoring of glucose effective, both doctor and patient need to be aware of its relevance, while blood glucose meters should be highly accurate and reproducible, as well as pain-minimizing and user-friendly.

About the Author

А. S. Pogorelova
First Moscow State Medical University named after I.M. Sechenov
Russian Federation


References

1. Алгоритмы специализированной медицинской помощи больным сахарным диабетом. Под ред. И.И. Дедова, М.В. Шестаковой. 6-е изд. М., 2013. Майоров А.Ю., Мельникова О.Г., Филиппов Ю.И. Самоконтроль гликемии - неотъемлемый компонент лечения сахарного диабета. Медицинский совет, 2013, 1: 90-97. American Diabetes Association. Standards of medical care in diabetes-2013. Diabetes Care, 2013, 36 (Suppl. 1): S11-S66. Anderson B, Ho J, Brackett J, Finkelstein D, Laffel L. Parental involvement in diabetes management tasks: relationships to blood glucose monitoring adherence and metabolic control in young adolescents with insulin dependent diabetes mellitus. Journal of Pediatrics, 1997, 130: 257265. Bragd J, Adamson U, Backlund LB, Lins PE, Moberg E, Oskarsson P Can glycaemic variability, as calculated from blood glucose self-monitoring, predict the development of complications in type 1 diabetes over a decade? Diabetes and Metabolism, 2008, 34 (6 Pt 1): 612-616. Breton MD, Kovatchev BP Impact of Blood Glucose Self-Monitoring Errors on Glucose Variability, Risk for Hypoglycemia, and Average Glucose Control in Type 1 Diabetes: An In Silico Study. Journal of Diabetes Science and Technology, 2010, 4(3): 562-570. Cavalot F, Pagliarino A, Valle M, Di Martino L, Bonomo K, Massucco P et al. Postprandial blood glucose predicts cardiovascular events and all-cause mortality in type 2 diabetes in a 14-year follow-up: lessons from the San Luigi Gonzaga Diabetes Study Diabetes Care, 2011, 34: 2237-2243. Coutinho M, Gerstein HC, Wang Y, Yusuf S. The relationship between glucose and incident cardiovascular events. A meta-regression analysis of published data from 20 studies of 95,783 individuals followed for 12.4 years. Diabetes Care, 1999, 22: 233-240. Global Guideline for Type 2 Diabetes. International Diabetes Federation, 2012.

2. Guerci B, Drouin P, Grange V, Bougneres P, Fontaine P, Kerlan V et al. Self-monitoring of blood glucose significantly improvesvmetabolic control in patients with type 2 diabetes mellitus: the Auto-Surveillance Intervention Active (ASIA) study Diabetes and Metabolism, 2003, 29: 587-594.

3. International Diabetes Federation, 2013: IDF Diabetes Atlas: www.idf.org/diabetesatlas

4. Halimi S, Charpentier G, Grimaldi A, Grenier JL, Baut F, Germain B, Magnette J. Effect on compliance, acceptability of blood glucose self-monitoring and HbA1c of a self-monitoring system developed according to patient's wishes. The ACCORD study Diabetes and Metabolism, 27 (6): 681-687.

5. Holman RR, Paul SK, Bethel MA, Matthews DR, Neil HA et al. 10 - Year Follow-up of Intensive Glucose Control in Type 2 Diabetes. New England Journal of Medicine, 2008, 359: 1577-1589.

6. Jansen JP Self-monitoring of glucose in type 2 diabetes mellitus: a Bayesian meta-analysis of direct and indirect comparisons. Current Medical Research and Opinion, 2006, 22: 671-681.

7. Martin S, Schneider B, Heinemann L, Lodwig V, Kurth HJ, Kolb H et al. Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study. Diabetologia, 2006, 49: 271-278.

8. Muchmore DB, Springer J, Miller M. Self-monitoring of blood glucose in overweight type 2 diabetic patients. Acta Diabetol, 1994, 31: 215-219.

9. Peel E, Parry O, Douglas M, Lawton J. Blood glucose self-monitoring in non-insulin-treated type 2 diabetes: a qualitative study of patients' perspectives. British Journal of General Practice, 2004, 54: 183-188.

10. Protection of Laboratory Workers from Occupationally Acquired infections; Approved Guideline - Third Edition. Clinical and Laboratory Standards Institute (CLSI), document M 29-A 3 (ISBN 1-56238-567-4). CLSI, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 190871898, 2005, USA.

11. Raine C.H. 3-rd. Self-monitored blood glucose: a common pitfall. Endocrine Practice, 2003, 9: 137-139.

12. Reichard P, Phil M. Mortality and treatment side effects during long-term intensified conventional insulin treatment in the Stockholm Diabetes Intervention study. Diabetes, 1994, 43 (2): 313-317.

13. Santiago JV. Lessons from the Diabetes Control and Complications Trial. Diabetes, 1993, 42 (11): 1549-1554.

14. Sarol JN, Nicodemus NA, Tan KM, Grava MB. Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: a meta-analysis (1966-2004). Current Medical Research and Opinion, 2005, 21: 173-184.

15. The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications of insulin-dependent diabetes mellitus. New England Journal of Medicine, 1993, 329 (14): 977-986.

16. UK Prospective Diabetes Study Group (UKPDS). Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes. Lancet, 1998, 352 (9131): 837-853.

17. Weber C, Schneider B, Lodwig V, Holm MV, Neeser K. Cost impact of blood glucose self-monitoring on complications of type 2 diabetes: a Swiss perspective (ROSSO study No. 11). SWISS MEDical WeeKLY, 2007, 137: 545-550.