Preview

Meditsinskiy sovet = Medical Council

Advanced search

Self-monitoring of blood glucose: an indispensable component of diabetes treatment

https://doi.org/10.21518/2079-701X-2013-1-2-90-97

Abstract

The article is an overview of glucose self-monitoring (GSM) in the treatment of diabetes. It article tells about the following: therapeutic targets of GSM before and after meals, adopted in Russia, providing individualized monitoring depending on age, presence of severe complications and risk of hypoglycemia; frequency of GSM at different types of glucose-lowering therapy; the significance of GSM for patient and physician; the functioning of photometric and electrochemical blood glucose meters; the issues of accuracy of measuring blood glucose adopted by the International Organization for Standardization of GSM systems; reasons of mistakes in measuring blood glucose related to contact of fingers with glucose particles, errors in code setting of test strips, external conditions (altitude, temperature, humidity), hematocrit, acidosis, hyperlipidemia and concentration of oxygen in blood, intake of a number of drugs; the process and guidelines of managing a diary as a primary method of storing GSM results; the data of global and Russian studies on the effectiveness of GSM. New methods of GSM are discussed in the section about continuous monitoring.

About the Authors

A. Yu. Mayorov
Endocrinology Research Center, Russia's Ministry of Health
Russian Federation


O. G. Melnikova
Endocrinology Research Center, Russia's Ministry of Health
Russian Federation


Yu. I. Filippov
Endocrinology Research Center, Russia's Ministry of Health
Russian Federation


References

1. Дедов И.И., Суркова Е.В., Майоров А.Ю., Галстян Г.Р., Токмакова А.Ю. Терапевтическое обучение больных сахарным диабетом. М.: Реафарм, 2004.

2. Суркова Е.В., Майоров А.Ю., Галстян Г.Р., Токмакова А.Ю. Обучение больных сахарным диабетом. Руководство для эндокринологов / под ред. Дедова И.И. ГУП «Медицина для вас». М., 2007.

3. Терапевтическое обучение больных. Программы непрерывного обучения для работников здравоохранения в области профилактики хронических заболеваний. Отчет рабочей группы ВОЗ, 1998.

4. Старостина Е.Г., Галстян Г.Р., Дедов И.И. Современные методы и средства самоконтроля обмена веществ при сахарном диабете // Проблемы эндокринологии. 1994. №1. С. 36–39.

5. Сахарный диабет: диагностика, лечение, профилактика / под ред. И.И. Дедова, М.В. Шестаковой. М.: ООО «Издательство “Медицинское информационное агентство”», 2011.

6. American Diabetes Association. Standards of medical care in diabetes-2012. Diabetes Care. 2013, 36, Suppl 1: S11–66.

7. Алгоритмы специализированной медицинской помощи больным сахарным диабетом / под ред. Дедова И.И., Шестаковой М.В. 5-й выпуск: Сахарный диабет, 2011, Приложение к №3 (http://dmjournal.ru/_mod_files/_upload/SD2011_3pr.pdf).

8. Monnier L., Lapinski H., Colette C. Contributions of Fasting and Postprandial Plasma Glucose Increments to the Overall Diurnal Hyperglycemia of Type 2 Diabetic Patients: Variations with increasing levels of HbA1c. Diabetes Care. 2003; 26: 881-5.

9. Сахарный диабет: острые и хронические осложнения / под ред. И.И. Дедова, М.В. Шестаковой. М.: ООО «Издательство “Медицинское информационное агентство”», 2011.

10. Parkin C.G., Hinnen D., Campbell R.K., Geil P., Tetrick D.L., Polonsky W.H. Effective Use of Paired Testing in Type 2 Diabetes. The Diabetes educator. 2009; 35: 915–27.

11. Aakre K.M., Watine J., Bunting P.S., Sandberg S., Oosterhuis W.P. Self-monitoring of blood glucose in patients with diabetes who do not use insulin—are guidelines evidence-based? Diabetic Medicine. 2012; 29: 1226-36.

12. Malanda U.L., Welschen L.M., Riphagen I.I., Dekker J.M., Nijpels G., Bot S.D. Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin. Cochrane Database Syst Rev. 2012; 1: CD005060.

13. Haupt A., Berg B., Paschen P., Dreyer M., Häring HU., Smedegaard J, Matthaei S. The effects of skin temperature and testing site on blood glucose measurements taken by a modern blood glucose monitoring device. Diabetes Technol Ther, 2005, 7: 597-601.

14. International Organization for Standardization. In vitro diagnostic test systems. Requirements for blood-glucose monitoring system for self-testing in managing diabetes mellitus. Reference number ISO 15197:2003 (E). Geneva: International Organization for Standardization; 2003.

15. Raine C.H., Schrock L.E., Edelman S.V., Mudaliar S.R.D., Zhong W., Proud L.J., Parkes J.L. Significant insulin dose errors may occur if blood glucose results are obtained from miscoded meters. Journal of Diabetes Science and Technology, 2007, 1: 205-10.

16. Grinsberg B.H. Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement. Journal of Diabetes Science and Technology, 2009, 3: 903-913.

17. Tonyushkina K., Nichols J.H. Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results. Journal of Diabetes Science and Technology, 2009, 3: 971-980.

18. Ervin K.R., Kiser E.J. Issues and implications in the selection of blood glucose monitoring technologies. Diabetes Technol Ther, 1999, 1: 3–11.

19. Bishop M.L., Fody E.P., Schoeff L.E. Clinical chemistry: principles, procedures, correlations. 5th ed. Baltimore: Lippincott Williams & Wilkins; 2005. p. 275.

20. Schleis TG. Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems. Pharmacotherapy. 2007, 2: 1313–1321.

21. The Diabetes Control and Complications Trial Research Group. The effects of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N. Engl. J. Med., 1993, v. 329, p. 977-986.

22. Майоров А.Ю., Галстян Г.Р., Двойнишникова О.М., Анциферов М.Б., Дедов И.И. Терапевтическое обучение в России: результаты 15-летнего наблюдения больных сахарным диабетом 1 типа. Сахарный диабет, 2005, № 3, с. 52-58.

23. Hermanides, J., M. Phillip, and J.H. DeVries. Current application of continuous glucose monitoring in the treatment of diabetes: pros and cons. Diabetes Care, 2011, 34, Suppl 2: p. S197-201.


Review

For citations:


Mayorov AY, Melnikova OG, Filippov YI. Self-monitoring of blood glucose: an indispensable component of diabetes treatment. Meditsinskiy sovet = Medical Council. 2013;(1-2):90-97. (In Russ.) https://doi.org/10.21518/2079-701X-2013-1-2-90-97

Views: 592


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2079-701X (Print)
ISSN 2658-5790 (Online)